- On-Line double conversion technology
- High frequency, transformerless design
- True sine wave output with less than 2% THD at linear load
- Zero transfer time
- Lithium-Iron Phosphate (LiFePO₄) battery technology
- UPS will start without mains present (DC / cold start)
- Built-in static bypass for overload and emergency conditions
- Generator compatible input
- Adaptable / extended run-time capability
- USB & RS232 communication ports
- SNMP monitoring optional
- LCD display with full UPS status reporting
| Model | |
| Model No. | PM11-VE01T-012L |
| Capacity | 1000VA / 800W |
| Input | |
| Input Voltage | 220 / 230 / 240 VAC (Settable) |
| Input Voltage Range | 160VAC to 299VAC |
| Input Frequency | 50 Hz ± 8% |
| Input Power Factor | ≥ 0.99 |
| Wiring Requirements | L/N + E |
| Output | |
| Transfer Time | Zero |
| Output Voltage On Inverter | 220 / 230 / 240 VAC (Settable) |
| Output Voltage Regulation | 1% |
| Frequency on Mains (Sync Mode) | 50 Hz ± 4 Hz |
| Frequency on Inverter | 50 Hz ± 0.1% (Crystal Controlled) |
| Inverter Wave Form | Sine |
| Total Harmonic Distortion (THD) |
Linear Load < 2% Non-Linear Load < 8% |
| Performance | |
| Efficiency |
On Mains Mode: ≥ 90% On Inverter Mode: ≥ 85% |
| Overload Capability |
105% for 60 seconds or 125% for 10 seconds or 150% for 0.3 seconds, then by-pass |
| Battery | |
| Batteries |
51.2VDC (16 Cell LiFePO4) 614Wh |
| Backup Time With 50% Load (400 watts) | ± 1.5 Hours |
| Backup Time With 75% Load (600 Watts) | ± 1 Hour |
| Charger | 4A Charger (Can upgrade on long run time to 16A), Constant Current (CC) / Constant Voltage (CV) and Float, turns off battery full. |
| Charger Protection |
Over voltage protection loop Preserve interface for over temperature Over pressure switch off interface |
| Re-Charge to 80% | ± 5 Hours |
| General | |
| Ambient Operation | 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity |
| Audible Noise At 1 M | < 55 dBA |
| Short Circuit Protection | Yes |
| Low Battery Shutdown | Yes |
| Controls | Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional) |
| Dimensions & Weight | |
| UPS Dimensions (W × D × H) & Weight | 190mm × 323mm × 420mm @ 18Kgs |
- On-Line double conversion technology
- True sine wave output with less than 2% THD at linear load
- Zero transfer time
- Lithium-Iron Phosphate (LiFePO₄) battery technology
- Extended battery life with high cycle capability
- UPS will start without mains present (DC / cold start)
- Static bypass for overload and emergency conditions
- Generator compatible input
- Unlimited / adaptable run-time capability
- USB & RS232 communication ports
- SNMP monitoring optional
- LCD display with input/output, frequency, load & battery information
- Short circuit protection
- Low battery automatic shutdown
- Over-voltage and over-temperature charger protection
- Up to 1.5 hours backup at 50% load
- Compact transformerless design
| Model | |
| Model No. | PM11-VE01T-012L |
| Capacity | 1000VA / 800W |
| Input | |
| Input Voltage | 220 / 230 / 240 VAC (Settable) |
| Input Voltage Range | 160VAC to 299VAC |
| Input Frequency | 50 Hz ± 8% |
| Input Power Factor | ≥ 0.99 |
| Wiring Requirements | L/N + E |
| Output | |
| Transfer Time | Zero |
| Output Voltage On Inverter | 220 / 230 / 240 VAC (Settable) |
| Output Voltage Regulation | 1% |
| Frequency on Mains (Sync Mode) | 50 Hz ± 4 Hz |
| Frequency on Inverter | 50 Hz ± 0.1% (Crystal Controlled) |
| Inverter Wave Form | Sine |
| Total Harmonic Distortion (THD) |
Linear Load < 2% Non-Linear Load < 8% |
| Performance | |
| Efficiency |
On Mains Mode: ≥ 90% On Inverter Mode: ≥ 85% |
| Overload Capability |
105% for 60 seconds or 125% for 10 seconds or 150% for 0.3 seconds, then by-pass |
| Battery | |
| Batteries |
51.2VDC (16 Cell LiFePO4) 614Wh |
| Backup Time With 50% Load (400 watts) | ± 1.5 Hours |
| Backup Time With 75% Load (600 Watts) | ± 1 Hour |
| Charger | 4A Charger (Can upgrade on long run time to 16A), Constant Current (CC) / Constant Voltage (CV) and Float, turns off battery full. |
| Charger Protection |
Over voltage protection loop Preserve interface for over temperature Over pressure switch off interface |
| Re-Charge to 80% | ± 5 Hours |
| General | |
| Ambient Operation | 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity |
| Audible Noise At 1 M | < 55 dBA |
| Short Circuit Protection | Yes |
| Low Battery Shutdown | Yes |
| Controls | Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional) |
| Dimensions & Weight | |
| UPS Dimensions (W × D × H) & Weight | 190mm × 323mm × 420mm @ 18Kgs |