  • On-Line double conversion technology
  • High frequency, transformerless design
  • True sine wave output with less than 2% THD at linear load
  • Zero transfer time
  • Lithium-Iron Phosphate (LiFePO₄) battery technology
  • UPS will start without mains present (DC / cold start)
  • Built-in static bypass for overload and emergency conditions
  • Generator compatible input
  • Adaptable / extended run-time capability
  • USB & RS232 communication ports
  • SNMP monitoring optional
  • LCD display with full UPS status reporting
Model
Model No. PM11-VE01T-012L
Capacity 1000VA / 800W
Input
Input Voltage 220 / 230 / 240 VAC (Settable)
Input Voltage Range 160VAC to 299VAC
Input Frequency 50 Hz ± 8%
Input Power Factor ≥ 0.99
Wiring Requirements L/N + E
Output
Transfer Time Zero
Output Voltage On Inverter 220 / 230 / 240 VAC (Settable)
Output Voltage Regulation 1%
Frequency on Mains (Sync Mode) 50 Hz ± 4 Hz
Frequency on Inverter 50 Hz ± 0.1% (Crystal Controlled)
Inverter Wave Form Sine
Total Harmonic Distortion (THD) Linear Load < 2%
Non-Linear Load < 8%
Performance
Efficiency On Mains Mode: ≥ 90%
On Inverter Mode: ≥ 85%
Overload Capability 105% for 60 seconds or 125% for 10 seconds or
150% for 0.3 seconds, then by-pass
Battery
Batteries 51.2VDC (16 Cell LiFePO4)
614Wh
Backup Time With 50% Load (400 watts) ± 1.5 Hours
Backup Time With 75% Load (600 Watts) ± 1 Hour
Charger 4A Charger (Can upgrade on long run time to 16A), Constant Current (CC) / Constant Voltage (CV) and Float, turns off battery full.
Charger Protection Over voltage protection loop
Preserve interface for over temperature
Over pressure switch off interface
Re-Charge to 80% ± 5 Hours
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 55 dBA
Short Circuit Protection Yes
Low Battery Shutdown Yes
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Dimensions & Weight
UPS Dimensions (W × D × H) & Weight 190mm × 323mm × 420mm @ 18Kgs
  • On-Line double conversion technology
  • True sine wave output with less than 2% THD at linear load
  • Zero transfer time
  • Lithium-Iron Phosphate (LiFePO₄) battery technology
  • Extended battery life with high cycle capability
  • UPS will start without mains present (DC / cold start)
  • Static bypass for overload and emergency conditions
  • Generator compatible input
  • Unlimited / adaptable run-time capability
  • USB & RS232 communication ports
  • SNMP monitoring optional
  • LCD display with input/output, frequency, load & battery information
  • Short circuit protection
  • Low battery automatic shutdown
  • Over-voltage and over-temperature charger protection
  • Up to 1.5 hours backup at 50% load
  • Compact transformerless design
Model
Model No. PM11-VE01T-012L
Capacity 1000VA / 800W
Input
Input Voltage 220 / 230 / 240 VAC (Settable)
Input Voltage Range 160VAC to 299VAC
Input Frequency 50 Hz ± 8%
Input Power Factor ≥ 0.99
Wiring Requirements L/N + E
Output
Transfer Time Zero
Output Voltage On Inverter 220 / 230 / 240 VAC (Settable)
Output Voltage Regulation 1%
Frequency on Mains (Sync Mode) 50 Hz ± 4 Hz
Frequency on Inverter 50 Hz ± 0.1% (Crystal Controlled)
Inverter Wave Form Sine
Total Harmonic Distortion (THD) Linear Load < 2%
Non-Linear Load < 8%
Performance
Efficiency On Mains Mode: ≥ 90%
On Inverter Mode: ≥ 85%
Overload Capability 105% for 60 seconds or 125% for 10 seconds or
150% for 0.3 seconds, then by-pass
Battery
Batteries 51.2VDC (16 Cell LiFePO4)
614Wh
Backup Time With 50% Load (400 watts) ± 1.5 Hours
Backup Time With 75% Load (600 Watts) ± 1 Hour
Charger 4A Charger (Can upgrade on long run time to 16A), Constant Current (CC) / Constant Voltage (CV) and Float, turns off battery full.
Charger Protection Over voltage protection loop
Preserve interface for over temperature
Over pressure switch off interface
Re-Charge to 80% ± 5 Hours
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 55 dBA
Short Circuit Protection Yes
Low Battery Shutdown Yes
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Dimensions & Weight
UPS Dimensions (W × D × H) & Weight 190mm × 323mm × 420mm @ 18Kgs
  • On-Line double conversion technology
  • High frequency, transformerless design
  • True sine wave output with less than 2% THD at linear load
  • Zero transfer time
  • Lithium-Iron Phosphate (LiFePO₄) battery technology
  • UPS will start without mains present (DC / cold start)
  • Built-in static bypass for overload and emergency conditions
  • Generator compatible input
  • Adaptable / extended run-time capability
  • USB & RS232 communication ports
  • SNMP monitoring optional
  • LCD display with full UPS status reporting
Model
Model No. PM11-VE03R-024L
Capacity 3000VA / 2700W
Input
Input Voltage 220 / 230 / 240 VAC (Settable)
Input Voltage Range 160VAC to 299VAC
Input Frequency 50 Hz ± 8%
Input Power Factor ≥ 0.99
Wiring Requirements L/N + E
Output
Transfer Time Zero
Output Voltage On Inverter 220 / 230 / 240 VAC (Settable)
Output Voltage Regulation 1%
Frequency on Mains (Sync Mode) 50 Hz ± 4 Hz
Frequency on Inverter 50 Hz ± 0.1% (Crystal Controlled)
Inverter Wave Form Sine
Total Harmonic Distortion (THD) Linear Load < 2%
Non-Linear Load < 8%
Performance
Efficiency On Mains Mode: 92%
On Inverter Mode: 89%
Overload Capability 105% for 60 Seconds or 125% for 10 seconds or
150% for 0.3 Seconds, then by-pass
Battery
Batteries 51.2VDC (16 Cell LiFePO4)
1250Wh
Backup Time With 50% Load (1350 watts) ± 40 Minutes
Backup Time With 75% Load (2025 Watts) ± 25 Minutes
Charger 4A Charger (Can upgrade on long run time to 16A), Constant Current (CC) / Constant Voltage (CV) and Float, turns off battery full.
Charger Protection Over voltage protection loop
Preserve interface for over temperature
Over pressure switch off interface
Re-Charge to 80% ± 5 Hours
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 50 dBA
Short Circuit Protection Yes
Low Battery Shutdown Yes
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Dimensions & Weight
UPS Dimensions (W × D × H) & Weight 440 × 400 × 86mm @ 25Kgs
  • On-Line double conversion technology
  • High frequency, transformerless tower design
  • True sine wave output with less than 2% THD at linear load
  • Zero transfer time
  • Lithium-Iron Phosphate (LiFePO₄) battery technology
  • UPS will start without mains present (DC / cold start)
  • Built-in static bypass for overload and emergency conditions
  • Generator compatible input
  • Adaptable / extended run-time capability
  • USB & RS232 communication ports
  • SNMP monitoring optional
  • LCD display with full UPS status reporting
Model
Model No. PM11-VE03T-024L
Capacity 3000VA / 2700W
Input
Input Voltage 220 / 230 / 240 VAC (Settable)
Input Voltage Range 160VAC to 299VAC
Input Frequency 50 Hz ± 8%
Input Power Factor ≥ 0.99
Wiring Requirements L/N + E
Output
Transfer Time Zero
Output Voltage On Inverter 220 / 230 / 240 VAC (Settable)
Output Voltage Regulation 1%
Frequency on Mains (Sync Mode) 50 Hz ± 4 Hz
Frequency on Inverter 50 Hz ± 0.1% (Crystal Controlled)
Inverter Wave Form Sine
Total Harmonic Distortion (THD) Linear Load < 2%
Non-Linear Load < 8%
Performance
Efficiency On Mains Mode: 92%
On Inverter Mode: 89%
Overload Capability 105% for 60 Seconds or 125% for 10 seconds or
150% for 0.3 Seconds, then by-pass
Battery
Batteries 51.2VDC (16 Cell LiFePO4)
1250Wh
Backup Time With 50% Load (1350 watts) ± 40 Minutes
Backup Time With 75% Load (2025 Watts) ± 25 Minutes
Charger 4A Charger (Can upgrade on long run time to 16A), Constant Current (CC) / Constant Voltage (CV) and Float, turns off battery full.
Charger Protection Over voltage protection loop
Preserve interface for over temperature
Over pressure switch off interface
Re-Charge to 80% ± 5 Hours
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 55 dBA
Short Circuit Protection Yes
Low Battery Shutdown Yes
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Dimensions & Weight
UPS Dimensions (W × D × H) & Weight 190mm × 323mm × 420mm @ 18Kgs
  • Generator-compatible AC input
  • True power-frequency isolation transformer
  • Intelligent battery management for extended battery life
  • Pure sine-wave output with ≤2% voltage distortion
  • Standard DC cold start without mains power
  • User-friendly LCD + LED display
  • Dual-language HMI interface
  • Built-in overload and short-circuit protection
  • 125% / 150% overload capacity
  • Flexible single-phase or three-phase input configuration
  • Single-phase output for versatile distribution
  • Suitable for data centres, telecoms, enterprise and other critical applications
Input
Input Voltage 1P2W 220/230VAC ±20% · 3P4W 380/400VAC ±20%
Frequency 50 / 60 Hz ± 10%
Bypass Input Voltage 1P2W 220VAC (230VAC optional)
Output
Inverter IGBT
Output Voltage 1P2W 220VAC (230VAC opt.) ±1%
Output Frequency 50 / 60 Hz ± 0.1%
Power Factor 0.8
Waveform Sine Wave
Voltage Distortion ≤ 2% (100% linear load)
Crest Factor 3 : 1
Battery
Battery Voltage 192 VDC
DC Cold Start Standard
General
Display & Alarm LCD + LED
Communication RS485 (RS232 opt.) / MODBUS
Temperature 0 ~ 40 °C
Humidity 0 ~ 95% non-condensing
Protection Overload · Short-circuit
Overload Capacity 125%: 10 min · 150%: 1 min
Noise < 50 dB at 1 m (front)
Standards YD/T 1095-2018
Capacity & Dimensions
Capacity 3 kVA
Dimensions W × D × H 424 × 460 × 180 mm
Weight 40 kg
  • Generator-compatible AC input
  • True power-frequency isolation transformer
  • Intelligent battery management for extended battery life
  • Pure sine-wave output with ≤2% voltage distortion
  • Standard DC cold start without mains power
  • User-friendly LCD + LED display
  • Dual-language HMI interface
  • Built-in overload and short-circuit protection
  • 125% / 150% overload capacity
  • Flexible single-phase or three-phase input configuration
  • Single-phase output for versatile distribution
  • Suitable for data centres, telecoms, enterprise and other critical applications
Input
Input Voltage 1P2W 220/230VAC ±20% · 3P4W 380/400VAC ±20%
Frequency 50 / 60 Hz ± 10%
Bypass Input Voltage 1P2W 220VAC (230VAC optional)
Output
Inverter IGBT
Output Voltage 1P2W 220VAC (230VAC opt.) ±1%
Output Frequency 50 / 60 Hz ± 0.1%
Power Factor 0.8
Waveform Sine Wave
Voltage Distortion ≤ 2% (100% linear load)
Crest Factor 3 : 1
Battery
Battery Voltage 192 VDC
DC Cold Start Standard
General
Display & Alarm LCD + LED
Communication RS485 (RS232 opt.) / MODBUS
Temperature 0 ~ 40 °C
Humidity 0 ~ 95% non-condensing
Protection Overload · Short-circuit
Overload Capacity 125%: 10 min · 150%: 1 min
Noise < 50 dB at 1 m (front)
Standards YD/T 1095-2018
Capacity & Dimensions
Capacity 3 kVA
Dimensions W × D × H 424 × 460 × 180 mm
Weight 40 kg
  • On-Line double conversion technology
  • Galvanic isolation for enhanced equipment protection
  • True sine wave output with ≤3% THD
  • Zero transfer time
  • Built-in static bypass for overload and emergency conditions
  • Generator compatible input
  • UPS will start without mains present (DC / cold start)
  • Adaptable / extended run-time capability
  • Intelligent battery charging management
  • Parallel operation of up to 4 units
  • USB communication with optional SNMP monitoring
  • LCD display with full UPS status reporting
Model
Model No. PM11-TB06E PM11-TB10E
Capacity VA (Watts) 6 000VA / 4 800W 10 000VA / 8 000W
Input
Input Voltage 230V AC ± 25% (165VAC to 275VAC)
Input Frequency 45Hz to 66Hz Automatically selected synchronisation range
Total Harmonic Distortion (THDi) ≤ 10% @ 100% Load
Input Power Factor ≥ 0.90
Output
Transfer Time Zero
Output Power Factor (PF) 0.8
Output Voltage On Inverter 230V AC ± 1%
(Adjustable 220V / 230V / 240V)
Frequency on Inverter 50 Hz Crystal Controlled
Inverter Wave Form Sine
THDu ≤ 3
Performance
Efficiency At Full Load > 92%
Crest Factor 3:1
Overload Capability 105% to 110% for 10 Minutes, then by-pass
130% for 1 minute, then by-pass
150% for 30 seconds, then by-pass
Battery & Charger
External Battery Pack Voltage 192VDC
Charger Intelligent charging management, effectively improving the life time of battery. Standard 5A Charger (10A Optional)
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 70% Load 45 dBA / > 70% Load 50 dBA
Short Circuit Protection Yes
Low Battery Shut Down Yes
Parallel Up to 4 units
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Approvals
Approvals IEC 62040-1-2008 / IEC62040-2-2006 / IEC62040-3-2011
ISO9001-2005 Quality / ISO14001-2005 Environmental Management
Dimensions & Weight
UPS Dimensions in Tower Format (W × D × H) 190mm × 426mm × 705mm 190mm × 485mm × 705mm
Weight 59Kg 62Kg
  • PM11-HF03RTE-100S Extended runtime – 100AH
  • High Frequency, transformerless design results in a small compact unit to suit an office or server room environment
  • On-Line double conversion technology
  • True sine wave output with less than 3% THD
  • Zero transfer time
  • Advanced battery management (ABM)
  • Batteries automatically charge when inverter is off
  • UPS will start without mains present (cold start)
  • Self diagnosis on UPS start up
  • Lightning and surge protection built in
  • USB Management Software (SNMP Optional)
  • LCD Display
  • Compatible with most brands of generator
Model
Model No. PM11-TB06S PM11-TB10S
Capacity VA (Watts) 6 000VA / 4 800W 10 000VA / 8 000W
Input
Input Voltage 230V AC ± 25% (165VAC to 275VAC)
Input Frequency 45Hz to 66Hz Automatically selected synchronisation range
Total Harmonic Distortion (THDi) ≤ 10% @ 100% Load
Input Power Factor ≥ 0.90
Output
Transfer Time Zero
Output Power Factor (PF) 0.8
Output Voltage On Inverter 230V AC ± 1%
(Adjustable 220V / 230V / 240V)
Frequency on Inverter 50 Hz Crystal Controlled
Inverter Wave Form Sine
THDu ≤ 3
Performance
Efficiency At Full Load > 92%
Crest Factor 3:1
Overload Capability 105% to 110% for 10 Minutes, then by-pass
130% for 1 minute, then by-pass
150% for 30 seconds, then by-pass
Battery & Charger
External Battery Pack Voltage 192VDC
Charger Intelligent charging management, effectively improving the life time of battery. Standard 5A Charger (10A Optional)
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 70% Load 45 dBA / > 70% Load 50 dBA
Short Circuit Protection Yes
Low Battery Shut Down Yes
Parallel Up to 4 units
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Approvals
Approvals IEC 62040-1-2008 / IEC62040-2-2006 / IEC62040-3-2011
ISO9001-2005 Quality / ISO14001-2005 Environmental Management
Dimensions & Weight
UPS Dimensions in Tower Format (W × D × H) 190mm × 426mm × 705mm 190mm × 485mm × 705mm
Weight 59Kg 62Kg
  • On-Line double conversion technology
  • Galvanic isolation for enhanced equipment protection
  • True sine wave output with ≤3% THD
  • Zero transfer time
  • Built-in static bypass for overload and emergency conditions
  • Generator compatible input
  • UPS will start without mains present (DC / cold start)
  • Adaptable / extended run-time capability
  • Intelligent battery charging management
  • Parallel operation of up to 4 units
  • USB communication with optional SNMP monitoring
  • LCD display with full UPS status reporting
Model
Model No. PM11-TB06E PM11-TB10E
Capacity VA (Watts) 6 000VA / 4 800W 10 000VA / 8 000W
Input
Input Voltage 230V AC ± 25% (165VAC to 275VAC)
Input Frequency 45Hz to 66Hz Automatically selected synchronisation range
Total Harmonic Distortion (THDi) ≤ 10% @ 100% Load
Input Power Factor ≥ 0.90
Output
Transfer Time Zero
Output Power Factor (PF) 0.8
Output Voltage On Inverter 230V AC ± 1%
(Adjustable 220V / 230V / 240V)
Frequency on Inverter 50 Hz Crystal Controlled
Inverter Wave Form Sine
THDu ≤ 3
Performance
Efficiency At Full Load > 92%
Crest Factor 3:1
Overload Capability 105% to 110% for 10 Minutes, then by-pass
130% for 1 minute, then by-pass
150% for 30 seconds, then by-pass
Battery & Charger
External Battery Pack Voltage 192VDC
Charger Intelligent charging management, effectively improving the life time of battery. Standard 5A Charger (10A Optional)
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 70% Load 45 dBA / > 70% Load 50 dBA
Short Circuit Protection Yes
Low Battery Shut Down Yes
Parallel Up to 4 units
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Approvals
Approvals IEC 62040-1-2008 / IEC62040-2-2006 / IEC62040-3-2011
ISO9001-2005 Quality / ISO14001-2005 Environmental Management
Dimensions & Weight
UPS Dimensions in Tower Format (W × D × H) 190mm × 426mm × 705mm 190mm × 485mm × 705mm
Weight 59Kg 62Kg
  • On-Line double conversion technology
  • Galvanic isolation for enhanced equipment protection
  • True sine wave output with ≤3% THD
  • Zero transfer time
  • Built-in static bypass for overload and emergency conditions
  • Generator compatible input
  • UPS will start without mains present (DC / cold start)
  • Adaptable / extended run-time capability
  • Intelligent battery charging management
  • Parallel operation of up to 4 units
  • USB communication with optional SNMP monitoring
  • LCD display with full UPS status reporting
Model
Model No. PM11-TB06E PM11-TB10S
Capacity VA (Watts) 6 000VA / 4 800W 10 000VA / 8 000W
Input
Input Voltage 230V AC ± 25% (165VAC to 275VAC)
Input Frequency 45Hz to 66Hz Automatically selected synchronisation range
Total Harmonic Distortion (THDi) ≤ 10% @ 100% Load
Input Power Factor ≥ 0.90
Output
Transfer Time Zero
Output Power Factor (PF) 0.8
Output Voltage On Inverter 230V AC ± 1%
(Adjustable 220V / 230V / 240V)
Frequency on Inverter 50 Hz Crystal Controlled
Inverter Wave Form Sine
THDu ≤ 3
Performance
Efficiency At Full Load > 92%
Crest Factor 3:1
Overload Capability 105% to 110% for 10 Minutes, then by-pass
130% for 1 minute, then by-pass
150% for 30 seconds, then by-pass
Battery & Charger
External Battery Pack Voltage 192VDC
Charger Intelligent charging management, effectively improving the life time of battery. Standard 5A Charger (10A Optional)
General
Ambient Operation 3000M Max Elevation, -10 to 40°C, 0 to 90% Humidity
Audible Noise At 1 M < 70% Load 45 dBA / > 70% Load 50 dBA
Short Circuit Protection Yes
Low Battery Shut Down Yes
Parallel Up to 4 units
Controls Mains Fail Alarm (Slow intermittent beep), Low Battery Alarm (Continuous beep), Mains on indicator, Charging indicator, By-Pass Indicator, LCD Display (Full UPS Status reporting), Diagnostic software via USB port (SNMP and dry contact optional)
Approvals
Approvals IEC 62040-1-2008 / IEC62040-2-2006 / IEC62040-3-2011
ISO9001-2005 Quality / ISO14001-2005 Environmental Management
Dimensions & Weight
UPS Dimensions in Tower Format (W × D × H) 190mm × 426mm × 705mm 190mm × 485mm × 705mm
Weight 59Kg 62Kg
  • High Frequency, transformerless design results in a small compact unit to suit an office or server room environment
  • On-Line double conversion technolog
  • True sine wave output with less than 3% THD
  • Zero transfer time
  • Advanced battery management (ABM)
  • Batteries automatically charge when inverter is off
  • UPS will start without mains present (cold start)
  • Self diagnosis on UPS start up
  • Lightning and surge protection built in
  • USB Management Software (SNMP Optional)
  • LCD Display
  • Compatible with most brands of generator
Input
Input Voltage 1P2W 220/230VAC ±20% · 3P4W 380/400VAC ±20%
Frequency 50 / 60 Hz ± 10%
Bypass Input Voltage 1P2W 220VAC (230VAC optional)
Output
Inverter IGBT
Output Voltage 1P2W 220VAC (230VAC opt.) ±1%
Output Frequency 50 / 60 Hz ± 0.1%
Power Factor 0.8
Waveform Sine Wave
Voltage Distortion ≤ 2% (100% linear load)
Crest Factor 3 : 1
Battery
Battery Voltage 192 VDC
DC Cold Start Standard
General
Display & Alarm LCD + LED
Communication RS485 (RS232 opt.) / MODBUS
Temperature 0 ~ 40 °C
Humidity 0 ~ 95% non-condensing
Protection Overload · Short-circuit
Overload Capacity 125%: 10 min · 150%: 1 min
Noise < 50 dB at 1 m (front)
Standards YD/T 1095-2018
Capacity & Dimensions
Capacity 3 kVA
Dimensions W × D × H 424 × 460 × 180 mm
Weight 40 kg
  • High Frequency, transformerless design results in a small compact unit to suit an office or server room environment
  • On-Line double conversion technolog
  • True sine wave output with less than 3% THD
  • Zero transfer time
  • Advanced battery management (ABM)
  • Batteries automatically charge when inverter is off
  • UPS will start without mains present (cold start)
  • Self diagnosis on UPS start up
  • Lightning and surge protection built in
  • USB Management Software (SNMP Optional)
  • LCD Display
  • Compatible with most brands of generator
CONTACT AN EXPERT Download Brochure

Product Features

On-Line, double conversion technology

The incoming mains supply is converted to DC, which is used to charge the batteries and, via the inverter, is converted back
to a clean AC output. This provides the connected equipment with the best possible power protection removing any spikes, surges or dips in voltage resulting in improved performance and reliability.

Transformer-less

This technology has been tried and tested and has proven itself to be exceptionally reliable. The use of high frequency technology dramatically reduces the size of the equipment and improves efficiency which in turn reduces the running cost.

USB and SNMP communication

The USB port allows the UPS to connect to a computer system for real time monitoring of the UPS. The user can set UPS parameters
such as charge rate, battery low voltage, and output voltages.
SNMP (Optional extra) allows the UPS to communicate via a network, and in conjunction with various software packages,
can supply information on the status of the UPS and perform a shut down if required.

Lithium Iron Battery
Technology (LiFePo4)

The Lithium-Iron Phosphate battery is regarded as the safest technology in batteries for multiple cycle applications. Each battery unit has a build in fire protection module for additional safety.

The LiFePo4 battery offers users a compact solution that is smaller and weighs less than the equivalent Lead Acid based designs. The battery is designed for 10 years life or 6000 cycles.

Generator compatible(LiFePo4)

The output power from the generator can vary as different loads come on and go off. The UPS will ensure that your equipment
is not damaged by the voltage fluctuations from the generator
.

Battery Management Unit (BMU)

The battery pack is constructed from 4 x 48VDC LiFePo4 battery packs connected in series providing the UPS with a 192VDC
battery pack. Each battery pack has an internal battery management unit (BMU), which in turn is controlled by a central Rack Battery Management Unit (RBMU) that communicates between the battery packs and the UPS.

The entire battery pack is controlled down to each cell, ensuring an even sharing of charge and discharge across the cells, resulting in maximum protection and reliability for the system.

Recharge

The UPS is equipped with a 10A charger (2,2KW) on the smaller machine, and an additional 5KW battery charger on the units
with larger battery packs, that will recover the battery to 80% within 4 to 5 hours.

DC start capability

Units are able to start and run with no mains input. Essentially the units can be run as a straight forward inverter if necessary.

LCD Display (UPS)

Gives users accurate information on the input and output voltages on the UPS, as well as frequency, load levels and available battery capacity. Audible alarm can be reset from the LCD display.

3-Step invertor design

The unique 3-step inverter design protects the inverter against sudden inrush current demands from the load, thereby improving
product reliability and uptime.